top of page
Wall-mount Hybrid Inverter

Wall-mount Hybrid Inverter

USh0Price
Quantity

Need help? Ask for a quote and we will be in touch.

ABOUT PRODUCT

The DK-PLUS is a high-capacity, intelligent inverter system with a rated output of 8000W to 11000W, paired with advanced MPPT (Maximum Power Point Tracking) solar technology and broad input voltage compatibility. It is ideal for solar power systems, backup energy storage, and hybrid power environments.

 

Category Parameter DK-PLUS
Model Info Model DK-PLUS
  Rated Power 8000W / 11000W
  Standard Battery Voltage 48VDC
  Installation Method Wall-mounted / Rack-mounted / Cabinet-mounted
Photovoltaic Parameters Working Mode MPPT
  Rated PV Input Voltage 360VDC
  MPPT Tracking Voltage Range 120–500V
  Max PV Input Voltage (VOC) 500V
  Max PV Input Power 5500W
  MPPT Tracking Number (Input Number) 1 road
Input Parameters DC Input Voltage Range 42–60VDC
  Rated AC Input Voltage 220/230/240VAC
  Mains Input Voltage Range 170–280VAC (UPS) / 120–280VAC (Inverter)
  Mains Input Frequency Range 40–55Hz (50Hz) / 55–65Hz (60Hz)
Output Parameters Output Efficiency (Inverter Mode) ≥94%
  Output Voltage 220/230/240VAC ±2%
  Output Frequency 50Hz ±0.5 / 60Hz ±0.5
  Output Efficiency (Mains Mode) ≥99%
  Battery Mode No-load Consumption ≤1% (rated power)
  No-load Loss in AC Mode ≤0.5% (rated power)
Battery Parameters Type Lead-acid / Custom Battery
  Max PV Input Current 18A / 18A
  Max PV Charging Current 120A
  Max AC Charging Current 100A
  Max Total Charging Current 160A
  Charging Method 3-stage (CC, CV, Float)
  Support for Lithium Battery Communication Yes, up to 6 units in parallel
  Max Number of Parallel Connections 6 Units
Battery Protection Undervoltage Alarm 10.5V (per cell, default)
  Voltage Protection Value +0.5V (per cell)
  Equalizing Charging Voltage 13.8V (per cell)
  Floating Charging Voltage 13.7V (per cell)
  Overvoltage Alarm 17V (per cell, default)
  Overvoltage Protection Value -1V (per cell)
  Overvoltage Recovery Voltage Automatic
Protection Functions Overload / Short Circuit Protection
  Temperature Protection ≥90°C Shutdown
  Protected Mode Auto (battery mode), breaker/fuse (mains)
Performance Specs Conversion Time ≤4ms
  Heat Dissipation Smart fan control
  Operating Temperature Range -10°C ~ 40°C
  Storage Temperature Range -15°C ~ 60°C
  Altitude ≤2000m (derate if higher)
  Relative Humidity 0–95% (non-condensing)